USXGMII SFP+ RJ45 电口模块

PRODUCT DESCRIPTION
SFP+-10GBASE-T Copper Small Form Pluggable (SFP) transceivers are based on the SFP Multi Source Agreement (MSA) . They are compatible with the 10Gbase-T / 5Gbase-T / 2.5Gbase-T / 1000base-T standards as specified in IEEE Std 802.3 . SFP+-10GBASE-T uses the SFP’s RX_LOS(must be pulled up on host) pin for link indication. If pull up or open SFP’s TX_DISABLE pin, PHY IC be reset.

PRODUCT FEATURES
Support 10Gbase-T / 5Gbase-T / 2.5Gbase-T / 1000base-T/100base-Tx on line port
Support USXGMII on host port
Hot-pluggable SFP footprint
Compact RJ-45 connector assembly
RoHS compliant and lead-free
Single +3.3V power supply
10 Gigabit Ethernet over Cat 6a cable
Ambient Operating temperature: 0°C to+70°C/-40°Cto +85°C

Cable Length

Line PortCableReachHost Port
10Gbase-TCAT6A F/FTP30mUSXGMII
5Gbase-TCAT5E50mUSXGMII
2.5Gbase-TCAT5E50mUSXGMII
1000base-TCAT5E100mUSXGMII 
100base-TxCAT5E100mUSXGMII 

SFP to Host Connector Pin Out

PinSymbolName/DescriptionRef.
1VEETTransmitter Ground  (Common with Receiver Ground)
2TFAULTTransmitter Fault. Not supported.
3TDISTransmitter Disable. Laser output disabled on high or open.1
4MOD_DEF(2)Module Definition 2. Data line for Serial ID.2
5MOD_DEF(1)Module Definition 1. Clock line for Serial ID.2
6MOD_DEF(0)Module Definition 0. Grounded within the module.2
7RS0No connection required
8LOSHigh indicates no linked.  low indicates linked.
9RS1No connection required
10VEERReceiver Ground  (Common with Transmitter Ground)
11VEERReceiver Ground  (Common with Transmitter Ground)
12RD-Receiver Inverted DATA out.  AC Coupled
13RD+Receiver Non-inverted DATA out.  AC Coupled
14VEERReceiver Ground  (Common with Transmitter Ground)
15VCCRReceiver Power Supply
16VCCTTransmitter Power Supply
17VEETTransmitter Ground  (Common with Receiver Ground)
18TD+Transmitter Non-Inverted DATA in. AC Coupled.
19TD-Transmitter Inverted DATA in.  AC Coupled.
20VEETTransmitter Ground  (Common with Receiver Ground)

Notes:
1. PHY disabled on TDIS  > 2.0V or open, enabled on TDIS < 0.8V
2. Should be pulled up with 4.7k – 10k Ohms on host board to a voltage between 2.0 V and 3.6 V. MOD_DEF(0) pulls line low to indicate module is plugged in.1

 +3.3V Volt Electrical Power Interface

+3.3 Volt Electrical Power Interface
ParameterSymbolMinTypMaxunitNotes/Conditions
Supply CurrentIs750900mA
Input Voltage Vcc3.133.33.47VReferenced to GND
Maximum VoltageVmax4V

The SFP+-10GBASE-T has an input voltage range of 3.3 V +/- 5%. The 4V maximum voltage is not allowed for continuous operation.

Low-Speed Signals
MOD_DEF(1)  (SCL)  and  MOD_DEF(2)  (SDA),  are  open  drain  CMOS  signals  (see section VII, “Serial Communication Protocol”).   Both MOD_DEF(1) and MOD_DEF(2) must be pulled up to host_Vcc

Low-Speed Signals,  Electronic Characteristics
ParameterSymbolMinMaxunitNotes/Conditions
SFP Output LOWVOL00.5V4.7k to 10k pull-up to host_Vcc,measured at host side of connector
SFP Output HIGHVOHhost_Vcc -0.5host_Vcc + 0.3V4.7k to 10k pull-up to host_Vcc,measured at host side of connector
SFP Input LOWVIL00.8V4.7k to 10k pull-up to Vcc,measured at SFP side of connector
SFP Input HIGHVIH2Vcc + 0.3V4.7k to 10k pull-up to Vcc,measured at SFP side of connector

High-Speed Electrical Interface
All high-speed signals are AC-coupled internally.

High-Speed Electrical Interface,  Transmission Line-SFP
ParameterSymbolMinTypMaxunitNotes/Conditions
Line FrequencyfL125MHz5-level encoding, per IEEE 802.3
Tx Output ImpedanceZout,TX100OhmDifferential, for all frequencies between1MHz and 125MHz
Rx Input ImpedanceZin,RX100OhmDifferential, for all frequencies between1MHz and 125MHz
High-Speed Electrical Interface,  Host-SFP
ParameterSymbolMinTypMaxunitNotes/Conditions
Single ended data input swingVinsing2501200mVSingle ended
Single ended data output swingVoutsing350800mVSingle ended
Rise/Fall TimeTr,Tf175psec20%-80%
Tx Input ImpedanceZin50OhmSingle ended
Rx Output ImpedanceZout50OhmSingle ended

General Specifications

General
ParameterSymbolMinTypMaxunitNotes/Conditions
Data RateBR110Gb/secIEEE 802.3 compatible.See Notes 1,2 below

Notes:Clock tolerance is +/- 50 ppm

Environmental Specifications
 Automatic crossover detection is enabled.  External crossover cable is not required

Environmental Specifications 
ParameterSymbolMinTypMaxunitNotes/Conditions
Operating TemperatureTop070°CCase temperature
Storage TemperatureTsto-4085°CAmbient temperature

Serial Communication Protocol
All  SFPs support the 2-wire serial communication protocol outlined in the SFP MSA. These SFPs use an MCU, can be accessed with address of A0h.

Serial Bus Timing, Requirements
ParameterSymbolMinTypMaxunitNotes/Conditions
I 2C Clock Rate 0200,000Hz

Recommended Application Circuit

Outline Dimensions (mm)

安科士 | AndXe Networks
企业邮箱:susie@andxe.com
企业手机:182 8033 7727
本产品仅展示部分参数,如有需要,请联系我们。

功率和波长测试

测试信号发射强度和波长,确保接收机的信号解码能力,以及从发射机到接收机的波长保持一致。

流量测试

测试误码率、丢包率,使其满足相应标准,保证收发器的性能。

光学性能测试

测试收发器的眼图情况、接收灵敏度、消光比、波长、发光、收光、电流、电压等,确保信号传输的质量、稳定性和可靠性。

光学性能测试

测试收发器的眼图情况、接收灵敏度、消光比、波长、发光、收光、电流、电压等,确保信号传输的质量、稳定性和可靠性。

兼容品牌:

思科 | 瞻博网络 | Arista | Brocade | HPE ProCurve | HPE Aruba | HPE BladeSystem | HPE H3C | H3C | 戴尔 | Extreme | HW | Generic | F-tone | 英特尔Netgear | IBM | NVIDIA/Mellanox(以太网)| Ciena | Fortinet | Avago | Avaya | 阿尔卡特朗讯 | D-Link | F5 | Ubiquiti | Mikrotik | Broadcom…..